Skip to product information
1 of 3

Tripp Lite by Eaton

Tripp Lite Pdumh32Hvnet 7.4Kw Single-Phase Switched Pdu, Lx Interface, 230V Outlets (16-C13), Iec-309 Blue 230V 32A, 3.6M Cord, 2U Rack-Mount, Taa

Tripp Lite Pdumh32Hvnet 7.4Kw Single-Phase Switched Pdu, Lx Interface, 230V Outlets (16-C13), Iec-309 Blue 230V 32A, 3.6M Cord, 2U Rack-Mount, Taa

SKU:PDUMH32HVNET

Regular price $717.64
Regular price Sale price $717.64
Sale Sold out
Shipping calculated at checkout.
          View full details
          Description
          Specifications
          Reviews, Que. & Ans.

          Description :

          7.4kW Single-Phase Switched PDU, LX Interface, 230V Outlets (16-C13), IEC-309 Blue 230V 32A, 3.6m Cord, 2U Rack-Mount, TAA

          Tripp Lite PDUMH32HVNET 7.4kW Single-Phase Switched PDU, LX Interface, 230V Outlets (16-C13), IEC-309 Blue 230V 32A, 3.6m Cord, 2U Rack-Mount, TAA. PDU types: Metered, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 16 AC outlet(s), AC outlet types: C13 coupler, Power plug: IEC309. Cable length: 3.65 m, Certification: IEC 60950-1. Nominal input voltage: 230 V, Maximum current: 32 A, AC input frequency: 50 - 60 Hz. Width: 444.5 mm, Depth: 317.5 mm, Dimensions (WxDxH): 445 x 317.5 x 89 mm

          Tripp Lite Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. Built-in LX Platform network management interface. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is displayed locally via front panel current meter or remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.

          230V Switched PDU with built-in web/network interface in 2U rackmount form factor; 32A capacity
          Blue 230V IEC-309 32A (2P+E) input cable; 12 ft. / 3.6m power cable included
          16 switched C13 outlets
          2U horizontal rackmount form factor
          Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
          Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets
          Network interface provides PDU control and data regarding input voltage, frequency and loading information
          Digital display reports load level information in amps
          Supports user-specified alarm notification thresholds
          DHCP/Manual configuration support
          10/100 Mbps auto-sensing
          Real-time clock backup maintains the time of day and date even if the PDU is unpowered
          Alert notifications via email or SNMP traps offer immediate event notification
          Firmware upgrade ability supports future product enhancements
          Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
          PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
          IP-based Auto Probe detects lost connectivity and restores service autonomously
          Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation formats
          Mounting ears are reversible for front or rear facing rackmount installation
          Included cord retention brackets
          TAA Compliant

          Specifications :

          General Information

          Manufacturer Tripp Lite by Eaton
          Manufacturer Part Number PDUMH32HVNET
          Manufacturer Website Address https://tripplite.eaton.com/
          Brand Name Tripp Lite by Eaton
          Product Series Switched
          Product Model PDUMH32HVNET
          Product Name Switched PDUMH32HVNET 16-Outlets 7.4kW PDU
          Product Type PDU
          UPC 037332157249
          Height3.5"
          Width17.5"
          Depth12.5"
          Weight (Approximate)13.70 lb

          Miscellaneous

          Package Contents
          • Switched PDUMH32HVNET 16-Outlets 7.4kW PDU
          • Rack Installation Brackets
          • Cable Retention Ties
          • SNMPWEBCARD Configuration Cable
          • PowerAlert Software Kit
          • User Manual
          Environmentally FriendlyYes

          Warranty

          Limited Warranty2 Year

          Customer Reviews

          Reviews 0
          Questions 0
          Ask your Question about this product