Description
Specifications
Description :
2-2.4kW Single-Phase Hot-Swap PDU, 200-240V 10A Outlets (8-C13), 2-C14, 200-240V Input, 6 ft. (1.83 m) Cords 2U Rack-MountTripp Lite PDUBHV10 2-2.4kW Single-Phase Hot-Swap PDU, 200-240V 10A Outlets (8-C13), 2-C14, 200-240V Input, 6 ft. (1.83 m) Cords 2U Rack-Mount. PDU types: Basic, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 9 AC outlet(s), AC outlet types: C13 coupler, Power plug: C14 coupler. Cable length: 1.83 m, Certification: UL60950 (USA), CSA (Canada), CE (IEC60950). Nominal input voltage: 200-240 V, Maximum current: 10 A, AC input frequency: 50 - 60 Hz. Width: 439.9 mm, Depth: 77 mm, Dimensions (WxDxH): 440 x 77 x 87 mm
Tripp Lite Hot-swap PDU systems support live-replacement of standard UPS systems for maintenance with no interruption of connected server or networking loads
PDUBHV10 is universally compatible with any Tripp Lite or other brand of 200-240V UPS rated up to 1500VA with a C14 input cable option
2U horizontal rackmount form factor compatible with 2 or 4 post racks
Supports space saving rear-post mounting in the same rack space as many Tripp Lite Rackmount UPS systems (select installations, see manual)
Pair of detachable PDU input cables connect to separate Utility and UPS power sources (2 C13-C14 interconnect cables included - user supplied alternate cabling supported)
8 C13 outlets support critical networking loads in both Utility and UPS operating modes
One additional C13 pass-through outlet supports UPS input power cord
Dual input power cables support PDU connection to separate Utility and UPS power sources
Manual transfer switch with lighted status indicators controls the source of power to connected equipment between Utility and UPS
Set the switch to UPS during normal operation and connected equipment will receive full-time conditioned power from the UPS
Set the switch to Utility to bypass the UPS and provide connected equipment with unfiltered power directly from the Utility line cord while the UPS system is removed and replaced with a fresh one
Once the new UPS is up and running with all connections restored, set the switch back to the UPS setting to once again provide fully-conditioned UPS power to connected equipment
Specifications :
General Information
Manufacturer | Tripp Lite by Eaton |
---|---|
Manufacturer Part Number | PDUBHV10 |
Manufacturer Website Address | https://tripplite.eaton.com/ |
Brand Name | Tripp Lite by Eaton |
Product Model | PDUBHV10 |
Product Name | PDUBHV10 PDU Dual Srce Hot Swap 200-240V 10A 8 Out |
Product Type | PDU |
UPC | 37332153906 |
Height | 3.4" |
---|---|
Width | 17.3" |
Depth | 3" |
Weight (Approximate) | 7.70 lb |
Package Contents |
|
---|---|
Environmentally Friendly | Yes |
Limited Warranty | 2 Year |
---|
- Choosing a selection results in a full page refresh.