Skip to product information
1 of 1

Tripp Lite by Eaton

Tripp Lite 1.9Kw Single-Phase Ats / Metered Pdu, 120V (16 5-15/20R), 2 L5-20P / 5-20P Adapters, 2 12Ft Cords, 1U Rack-Mount

Tripp Lite 1.9Kw Single-Phase Ats / Metered Pdu, 120V (16 5-15/20R), 2 L5-20P / 5-20P Adapters, 2 12Ft Cords, 1U Rack-Mount

SKU:PDUMH20AT

Regular price $436.87
Regular price Sale price $436.87
Sale Sold out
Shipping calculated at checkout.
          View full details
          Description
          Specifications
          Reviews, Que. & Ans.

          Description :

          1.9kW Single-Phase ATS / Metered PDU, 120V (16 5-15/20R), 2 L5-20P / 5-20P adapters, 2 12ft Cords, 1U Rack-Mount

          Tripp Lite 1.9kW Single-Phase ATS / Metered PDU, 120V (16 5-15/20R), 2 L5-20P / 5-20P adapters, 2 12ft Cords, 1U Rack-Mount. PDU types: Metered, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 16 AC outlet(s), AC outlet types: NEMA 5–15R,NEMA 5–20R, Input connection type: NEMA 5-20P, NEMA L5-20P. Cable length: 3.6 m, Certification: UL 60950-1, CSA, Class A, NOM. Nominal input voltage: 100-127 V, Maximum current: 20 A, AC input frequency: 60 Hz. Width: 444.5 mm, Depth: 368.3 mm, Dimensions (WxDxH): 444 x 368 x 44.4 mm

          Tripp Lite Metered ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
          - 120V 20A Automatic Transfer Switch (ATS) / Metered PDU (Agency de-rated to 16A continuous)
          - Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord
          - Digital display continuously reports total output power consumption in amps
          - 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
          - 16 built-in NEMA 5-15/20R outlets (8 front / 8 rear)
          - Set of two 12 ft. / 3.6m NEMA L5-20P input cables with set of two 5-20P adapters support connection to separate PRIMARY and SECONDARY inputs
          - ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
          - ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
          - Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
          - On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
          - Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
          - Built-in card slot supports optional SNMPWEBCARD for permanent upgrade to a switched & monitored PDU system
          - Outlets are factory programmed for sequential turn-on at 250 millisecond intervals when the PDU is first energized to prevent inrush-related equipment interaction on startup
          - Front panel LEDs confirm power availability on both input lines
          - TAA Compliant Version Available - Order Tripp Lite PDUMH20ATAA

          Specifications :

          General Information

          Manufacturer Tripp Lite by Eaton
          Manufacturer Part Number PDUMH20AT
          Manufacturer Website Address https://tripplite.eaton.com/
          Brand Name Tripp Lite by Eaton
          Product Model PDUMH20ATNET
          Product Name PDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
          Product Type PDU
          UPC 037332126665
          Height1.8"
          Width17.5"
          Depth14.5"
          Weight (Approximate)12.20 lb

          Miscellaneous

          Package Contents
          • PDUMH20AT PDU Metered ATS 120V 20A 16 Outlet
          • PDU with attached L5-20P input power cord
          • Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
          • Two NEMA L5-20R to NEMA 5-20P plug adapters
          • User manual with warranty information
          Environmentally FriendlyYes

          Warranty

          Limited Warranty2 Year

          Customer Reviews

          Reviews 0
          Questions 0
          Ask your Question about this product