Description
Specifications
Description :
7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU, Two 32A IEC309 32A Blue Inputs, 1 IEC309 32A Outlet, 1UTripp Lite PDUMNH32HVAT 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU, Two 32A IEC309 32A Blue Inputs, 1 IEC309 32A Outlet, 1U. PDU types: Monitored, Rack capacity: 1U, Mounting: Horizontal. AC outlets quantity: 2 AC outlet(s), Power plug: IEC309. Cable length: 3.05 m, Certification: CE. Nominal input voltage: 200-240 V, Maximum current: 32 A, AC input frequency: 50 - 60 Hz. Width: 430 mm, Depth: 355.6 mm, Dimensions (WxDxH): 430 x 356 x 44 mm
The PDUMNH32HVAT 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has one IEC 309 32A Blue outlet for connecting a single device or an additional 230V multi-outlet PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV.
Dual 10-ft. (3.05 m) input cords, each with IEC 309 32A Blue input plug, connect to any two separate primary and secondary input power sources, including out-of-phase input sources. The PDU constantly evaluates the power quality of both inputs. To ensure connected equipment remains powered, dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable.
Built-in LX Platform network management interface allows remote access to the PDU for power monitoring, configuration, control and to receive user-configurable notifications. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. Provides real-time load/current data with billing-grade accuracy (±1 percent). It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
Primary and Secondary Inputs for Power Redundancy
Enables redundant power configurations for network devices with a single input cord or other non-redundant power supply configuration
Two IEC 309 32A Blue (2P+E) inputs, each with 10-ft. (3.05 m) cord, connect to separate primary and secondary input power sources
Any two input power sources are supported for primary and secondary inputs, including out-of-phase power sources
Built-In IEC 309 32A Blue Outlet
Power a single 32A plug-in device or multiple network devices through a connected 32A 200-240V multi-outlet PDU, such as Tripp Lite's PDUMV32HV metered PDU input (sold separately)
Automatic Transfer Switching
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
1-5 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Touchscreen LCD
Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor
Advanced Network Monitoring
Pre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities
PADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
Broad Communications Compatibility
Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH
Supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network
Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.
10/100 Mbps auto-sensing for communication with 10/100 Base-T networks
Mounts Horizontally in 1U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
Included PDU4PKIT rail kit adds rear rack-mounting support
Specifications :
General Information
Manufacturer | Tripp Lite by Eaton |
---|---|
Manufacturer Part Number | PDUMNH32HVAT |
Manufacturer Website Address | https://tripplite.eaton.com/ |
Brand Name | Tripp Lite by Eaton |
Product Model | PDUMNH32HVAT |
Product Name | PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU |
Product Type | PDU |
UPC | 037332187871 |
Height | 1.7" |
---|---|
Width | 16.9" |
Depth | 14" |
Weight (Approximate) | 18.28 lb |
Package Contents |
|
---|---|
Environmentally Friendly | Yes |
Limited Warranty | 2 Year |
---|