Description
Specifications
Description :
Isolator Series 120V 1000W UL60601-1 Medical-Grade Isolation Transformer with 4 Hospital-Grade OutletsTripp Lite Isolator Series 120V 1000W UL60601-1 Medical-Grade Isolation Transformer with 4 Hospital-Grade Outlets. AC outlets quantity: 4 AC outlet(s), AC outlet types: NEMA 5–15R, Nominal input voltage: 120 V. Power plug: NEMA 6–15P. Product colour: White, EMI/RFI noise filtering: 65 dB, Country of origin: Taiwan. Cable length: 3.05 m, Weight: 16.7 kg, Width: 184.2 mm. Certification: TAA, UL60601-1
Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of medical electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1000HG includes 4 widely spaced NEMA 5-15R hospital-grade output receptacles, a 10-ft. power cord, hospital-grade input plug, circuit breaker overload protection, and lighted power switch. Rugged all-metal unit housing; ships ready for placement in any industrial, medical, office or network environment. PLUG/OUTLETS: Input - NEMA 5-15P Hospital Grade; Output - 4 NEMA 5-15R Hospital Grade ELECTRICAL: 120V AC, 60Hz, 8.3A (Requires NEMA 5-15R wall receptacle)
- The IS1000HG Medical Grade Isolation Transformer offers line isolation and continuous noise filtering
- Internal low-impedance isolation transformer with Faraday shield offers 100% isolation from the input AC line
- Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of
- sensitive electronic equipment in patient-care areas
- Reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps
- Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment
- Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades
- Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops
- Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power
- environments to harmless levels
- Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode
- Includes 4 widely spaced NEMA5-15R hospital grade output receptacles, a 10-ft power cord, hospital grade input plug, circuit breaker overload protection
- and lighted power switch
- Rugged all-metal unit housing; ships ready for upright tower placement in any industrial, medical, office or network environment
Specifications :
General Information
Manufacturer | Tripp Lite by Eaton |
---|---|
Manufacturer Website Address | https://tripplite.eaton.com/ |
Brand Name | Tripp Lite by Eaton |
Product Model | IS1000HG |
Product Name | Isolation Transformer - Medical Grade Line Noise Reduction and Spike Suppression |
Product Type | Surge Suppressor/Protector |
UPC | 037332116215 |
Height | 7.3" |
---|---|
Width | 7.3" |
Depth | 10.5" |
Weight (Approximate) | 36.80 lb |
Package Contents |
|
---|---|
Environmentally Friendly | Yes |
Limited Warranty | 2 Year |
---|
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/products/Tripp-Lite-Isolator-Series-120V-1000W-UL60601-1-Medical-Grade-Isolation-Transformer-with-4-Hospital-Grade-Outlets.jpg?v=1681914039&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/products/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-2.jpg?v=1681971539&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/products/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-3.jpg?v=1681971543&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/products/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-4.jpg?v=1681971548&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/products/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-5.jpg?v=1681971552&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/files/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-6.jpg?v=1705880040&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/files/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-7.jpg?v=1705880045&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/files/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-8.jpg?v=1705880050&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/files/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-9.jpg?v=1705880055&width=1445)
![Tripp Lite Isolator Series 120V 1000W Ul60601-1 Medical-Grade Isolation Transformer With 4 Hospital-Grade Outlets](http://tecisoft.com/cdn/shop/files/Tripp-Lite-Isolator-Series-120V-1000W-Ul60601-1-Medical-Grade-Isolation-Transformer-With-4-Hospital-Grade-Outlets-10.jpg?v=1705880059&width=1445)
- Choosing a selection results in a full page refresh.
- Opens in a new window.