Skip to product information
1 of 1

Tripp Lite by Eaton

Tripp Lite 5.8Kw Single-Phase Switched Pdu, 208/240V Outlets (16 C13), L6-30P Input, 3.66 M (12-Ft.) Cord, 2U Rack-Mount

Tripp Lite 5.8Kw Single-Phase Switched Pdu, 208/240V Outlets (16 C13), L6-30P Input, 3.66 M (12-Ft.) Cord, 2U Rack-Mount

SKU:PDUMH30HVNET

Regular price $1,221.00 CAD
Regular price Sale price $1,221.00 CAD
Sale Sold out
Shipping calculated at checkout.
          View full details
          Description
          Specifications
          Reviews, Que. & Ans.

          Description :

          5.8kW Single-Phase Switched PDU, 208/240V Outlets (16 C13), L6-30P Input, 3.66 m (12-ft.) Cord, 2U Rack-Mount

          Tripp Lite 5.8kW Single-Phase Switched PDU, 208/240V Outlets (16 C13), L6-30P Input, 3.66 m (12-ft.) Cord, 2U Rack-Mount. PDU types: Switched, Rack capacity: 2U, Mounting: Horizontal. AC outlets quantity: 16 AC outlet(s), AC outlet types: C13 coupler, Power plug: NEMA L6-30P. Cable length: 3.6 m, Certification: UL 60950-1, Class A, NOM. Nominal input voltage: 200-240 V, Maximum current: 30 A, AC input frequency: 50 - 60 Hz. Width: 444.5 mm, Depth: 317.5 mm, Dimensions (WxDxH): 445 x 317.5 x 89 mm

          Tripp Lite single phase Switched PDU / Power Distribution Unit offers advanced network control and monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle, monitor site electrical conditions and remotely monitor output power consumption. PowerAlert interface supports remote control and custom notification of user-specified conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be electronically locked off to prevent the connection of unauthorized hardware. PDU output current consumption in amps is continuously displayed locally via visual meter and remotely via web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
          - Switched 30A 208/240V PDU, 2U horizontal rackmount format
          - Reports voltage, frequency & load level via ethernet interface
          - Visual current meter, Reversible housing
          - NEMA L6-30P input plug with attached 12 ft. / 3.6m line cord
          - 16 switched C13 outlets with cord retention brackets
          - Temperature, humidity and contact closure monitoring options


          - Rackmount PDU
          - Installable 2U mounting brackets

          - 30A 208/240V Switched Power Distribution Unit / PDU with built-in web/network interface (Agency derated to 24A continuous)
          - Attached L6-30P 208/240V single phase input, 12 ft. / 3.6m input cord
          - 2U horizontal rackmount form factor
          - 16 switched c13 outlets
          - Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis

          - Enables reboot of locked equipment, custom power-on/power-off sequences, load-shedding of optional loads and disabling unused outlets

          - Network interface provides PDU control and data regarding input voltage and total output load level in amps

          - Digital display continuously reports output load in amps in 3 segments (load bank 1, load bank 2, total)

          - Supports user-specified alarm notification thresholds

          - In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors

          - DHCP/Manual configuration support

          - 10/100 Mbps auto-sensing
          - Real-time clock backup maintains the time of day and date even if the PDU is unpowered

          - Tiered access privileges allow an administrator and a guest to login via web browser

          - Alert notifications via email or SNMP traps offer immediate event notification

          - Firmware upgrade ability supports future product enhancements

          - Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols

          - Fully compatible with FREE PowerAlert Network Management System / NMS Software

          - 2U horizontal rack installation supported in 2 or 4 post racks with included mounting brackets
          - Mounting brackets support wall-mount and under-counter installation in many applications
          - Included cord retention brackets

          Specifications :

          General Information

          Manufacturer Tripp Lite by Eaton
          Manufacturer Part Number PDUMH30HVNET
          Manufacturer Website Address https://tripplite.eaton.com/
          Brand Name Tripp Lite by Eaton
          Product Model PDUMH30HVNET
          Product Name PDUMH30HVNET PDU Switched 208V - 240V 30A 16 Outlet
          Product Type PDU
          UPC 037332139320
          Height3.5"
          Width17.5"
          Depth12.5"
          Weight (Approximate)13.80 lb

          Miscellaneous

          Package Contents
          • PDUMH30HVNET PDU Switched 208V - 240V 30A 16 Outlet
          • Rackmount PDU
          • 4 post compatible mounting brackets
          Environmentally FriendlyYes

          Warranty

          Limited Warranty2 Year

          Customer Reviews

          Reviews 0
          Questions 0
          Ask your Question about this product